Introduction to wooden door installation specifications and detailed acceptance criteria

Wooden door installation specification introduces the detailed acceptance of wooden door installation acceptance criteria

The content included in this specification: the scope of application of the specification, the normative reference documents, the interpretation of the relevant professional words, the basic provisions for the installation of indoor wooden doors, and the acceptance criteria.

1 Scope

This standard specifies the basic regulations and acceptance specifications for the installation of indoor wooden doors.

This standard is applicable to the installation and acceptance of indoor wooden doors. It is also applicable to disputes and arbitration caused by improper installation of doors and door leaf deformation.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. For dated documents, all subsequent amendments (not including errata content) or revisions do not apply to this standard. However, parties to agreements based on this standard are encouraged to study whether they can be used. The latest version. For undated references, the latest edition applies to this standard.

WB/T1024-2006 wooden door

JGJ103 One% plastic door and window installation and acceptance procedures

JG/T187-2006 sealing strip for building doors and windows

JG/T 187-2006 Sealing strip for building doors and windows

JG/T130-2000 polyvinyl chloride (PVC) door and window semi-circular lock

JG/T130-2000 polyvinyl chloride (PVC) support

JG/T 130-2000 polyvinyl chloride (PVC) drive locker

JG/T130-2000 polyvinyl chloride (PVC) fixing sheet

JG/Tl30-2000 polyvinyl chloride (PVC) hinge (hinge)

3 definition

3.1 Hole of Hole (Size of Hole)

The size of the opening of the finished surface (floor, wall tile) on the ground and wall.

3.2 Width of Hole

The minimum distance between the horizontal and horizontal directions.

3.3 Thickness of Hole

The minimum thickness after the wall is finished.

3.4 Height of Hole

The minimum distance between the height direction and the vertical direction.

4 Basic regulations

4.1 Preparation before construction

4.1.1 Measurement of door openings

Wooden doors must be measured for the user's door opening before being designed, fabricated and installed. The measurement needs to be based on the ground surface after paving the floor tiles or the floor. If the ground construction is not completed, the thickness of the floor decoration material should be reserved.

1) Measurement of door width

Horizontally measure the distance between the left and right of the door hole, and select more than five measuring points for measurement. The minimum value (minus the door frame adjustment margin) is the door frame extension size; the tolerance is within the range of -15cm-1+5cm; if the measured value of the five points is greater than the measured value 20mm, the user should be required to trim the hole.

2) Measurement of door height

Vertically measure the upper and lower distances of the door opening, and select more than three measuring points for measurement, wherein the minimum value (minus the door frame adjustment margin) is the door frame extension size; the tolerance is -5mm + l0mm; if the measured value of the three points is greater than 10mm, then The user should be required to trim the hole.

3) Measurement of the thickness of the door wall

The thickness of the wall is measured horizontally, and more than five measuring points are selected for measurement. The maximum value is the wall thickness. If the wall surface needs to be decorated, the thickness of the door wall thickness must be added to the thickness of the decoration material, and the tolerance is in the range of O + 5 mm.

4.2 Locking door When marking the door, the lock door should be marked, and the marking of the opening and closing direction of the door fan and the switch face of the door in the WB/T1024-2006 wooden door shall be marked, that is, the clockwise direction shall be closed. , indicated by "5", closed counterclockwise, indicated by "6".

4.2.1 before confirmation before installation, the installation method should, installation requirements, duration, etc., with their instructions to the user and recognized. 4.3 Basic requirements for the installation environment.

4.3.1 Dimensional requirements for door openings

The size of the door opening should conform to the current 4B of WB/T 1024-2006 "Wooden Door", which is preferred to 700 mm x 2000 mm, 760 mm x 2000 mm, 800 mm x 2000 mm, 90 mm x 2000 mm, 700 mm x 2100 mm. , 760 mm x 2100 mm, 800 mm x 2100 mm, 900 mm x 2100 mm, 1200 mm x 2100 mm.

4.3.2 Requirements for installation conditions

The installation of wooden doors shall be carried out after the wet work of the wall is hardened and after concealed works, ceiling works, wall works, hydropower projects are completed, and protective measures shall be taken when it is required to be carried out before wet work.

After the product arrives at the installation site, the installation conditions must be checked to meet the requirements of Table 1.

Table l installation conditions requirements

Test item tolerance

The wall perpendicularity of the hole wall is ≤2

The verticality of the side wall of the hole is ≤10

Hole wall level ≤5

The ground level of the hole is ≤2

The outer dimensions of the sleeve and the size of the mounting hole allow for error 5-20

The temperature of the installation environment should not be lower than 5 °C

Installation temperature range of foam rubber 10-25

Hole wall humidity 1) <25%

The strength and thickness of the wall shall comply with the housing acceptance requirements

Cleaning around the installation hole requires preparation of a site larger than 2.5m × 1.5m (length x width), the ground is smooth, no dust and debris, to facilitate the assembly of the door cover.

Note: 1) If the humidity is >25%, the moisture barrier should be installed on the installation.

Acid And Alkali Resistant Workwear

Acid Resistant Suits,Acid Protective Coveralls,Acid Resistant Pants,Alkali Resistant Workwear

Xinxiang Worldbest Patron Saint Co., Ltd , https://www.xxhyhsworkwear.com